Past holiday work - 2024 autumn holidays
2024 winter school holidays
Work that may involve hazardous materials during the school holidays will take place at the below schools.
Check the list to find out if your school is included. All work is weather permitting. Please note, ACM refers to “asbestos containing materials”.
Winter holiday works notification - July 2024
(PDF 115 KB)
School holiday work school list
School |
What work we’re doing and where |
More detail about the work involving hazardous materials |
---|---|---|
Mould testing and remediation (if required) in Buildings E, F and G. |
Mould testing of eaves and window panels. If required, remediation work will also by completed. |
|
Removing ceiling material in walkway outside the student toilets in Building B, and Stage Area in the Hall. |
Removal of ceiling sheets known to contain bonded asbestos-containing material. Currently undisturbed and in good condition. |
|
Replacement of flooring in the Building B woodwork room. |
Current vinyl tiles known to contain asbestos material. Currently undisturbed and in good condition. |
|
Replacing ceiling and stairs in a demountable classroom. |
Removal of AC sheeting, stair landing and stair treads known to contain ACM. Currently undisturbed and in good condition. |
|
Replacement of carpet in the movement area of Building A and the cleaner's storeroom in Building K. |
Removal of vinyl tiles with known bonded ACM underneath the existing carpet. Currently undisturbed and in good condition. |
|
Replacement of carpet in one room in Building E. |
Removal of vinyl tiles with known bonded ACM underneath the existing carpet. Currently undisturbed and in good condition. |
|
Demolition and removal of bonded asbestos material from Building G eave sheets. |
Removal of eave sheets known to contain bonded asbestos material. Currently undisturbed and in good condition. |
|
Replacing flooring in a classroom in Building B. |
Removal of vinyl tiles suspected of containing ACM. Currently undisturbed and in good condition. |
|
Replacement of carpets in multiple rooms across Building G. |
Removal of vinyl tiles suspected of containing ACM. Currently undisturbed and in good condition |
|
Switch board upgrades to buildings A,B,C,D and F. |
Remediation of assumed ACM in switchboard links. |
|
Continuation of turf works. |
None |
|
Roof restoration and mould remediation of 3 demountable classrooms. |
Mould remediation of affected surfaces. |
|
Replacing a ceiling sheet in Building G. |
Removal of AC ceiling sheet suspected of containing ACM. Currently encapsulated. |
|
Upgrading of electrical power board in Building A. |
Removal of backing board material containing known ACM in Building A. Currently undisturbed and in good condition. |
|
Replacement of carpets in multiple rooms across Building E. |
Removal of vinyl tiles suspected of containing ACM. Currently undisturbed and in good condition |
|
Refurbishing of toilets in Building X |
Removal of bonded ACM located within the toilet partitions. Currently undisturbed and in good condition. |
|
Installation of outdoor covered walkways. |
Excavation of post holes for walkway footings in outdoor areas near the western sports oval may include working with known ACM. |
|
Replacing ceiling sheets in one classroom in Building A and 2 classrooms and a movement area in Building B. |
Removal of AC ceiling sheets suspected of containing ACM. Currently undisturbed and in good condition. If lead dust is found in the roof cavity during this work, it will also be remediated at the same time. |
|
Replacement of flooring in one room in Building E. |
Replacement of vinyl tiles with known bonded ACM. Currently undisturbed and in good conition. |
|
Replacing flooring in the new support unit classroom in Building F. |
Removal of vinyl tiles with known bonded ACM underneath the existing carpet. Currently undisturbed and in good condition. |
|
Replacing carpet in a staffroom in Building G. |
Removal of vinyl tiles suspected of containing ACM. Currently undisturbed and in good condition. |
|
Repairs to existing concrete paths and walkways and resurfacing grassed areas. |
Remediation of in-ground asbestos in the seating area adjacent to PE staffroom and baseball field on grassed playing area. |
|
Replacing external wall cladding and internal walls in the uniform shop, Building P. |
Remediation work has the potential to disturb known ACM in external eaves. This area is currently undamaged and in good condition. |
|
Remediation of LED dust and asbestos material in Buildings C,D and E. |
ACM located in subfloor and ceiling voids. |
|
Replacement of carpet in two rooms in Building D. |
Removal of vinyl tiles with known bonded ACM underneath the existing carpet. Currently undisturbed and in good condition. |
|
Repairing of small holes found in ceilings in storeroom in Building A and staff room in Building B |
Testing and removal of suspected ACM located in the ceiling void |
|
Replacement of flooring in Building E. |
Removal of vinyl tiles with known bonded ACM underneath the existing carpet. Currently undisturbed and in good condition. |
|
Construction of a sensory garden. |
None |
|
Installation of window screens and internal fencing. |
None |
|
Replacement of server cabinets in a storeroom in Building A and 5 electrical distribution boards in Building A and B. |
Removal of server cabinets and electrical distribution boards assumed to contain ACM. |